When a permanent record of load data is the goal, the Massload Wired Tension Link to Computer connects to a DSCUSB interface with lower sampling rate, plugging directly into any Windows PC with no external power required.
The free DSC Toolkit software handles configuration and calibration, as well as logging, charts, and export of load data to CSV, ideal for general-purpose monitoring, proof load testing, and compliance recording.
| Capacity | 10,000 lb (4,536 kg), 25,000 lb (11,340 kg), 50,000 lb (22,680 kg), 75,000 lb (34,019 kg), 100,000 lb (45,359 kg), 150,000 lb (68,039 kg), 250,000 lb (113,400 kg); Custom capacity available upon request |
|---|---|
| Accuracy | 0.1% FS |
| Safe Overload | 200% of full scale |
| Ultimate Overload | 400% of full scale |
| Full Scale Output | 2 mV/V nominal |
| Maximum Excitation | 10 V DC |
| Bridge Resistance | 350 Ω |
| Operating Temperature | −40°C to +80°C (-40F to +176F) |
| Compensated Temperature | −10°C to +40°C (+14F to +104F) |
| Sealing Standard | IP67 |
| Material | High-strength alloy steel |
| Protective Coating | Electroless nickel coating |