ICA5ATEX Embedded Load Cell Signal Conditioner

IMAGES
ATEX

The Mantracourt ICA5A is a subminiature ATEX intrinsically safe signal conditioner delivering a 2-wire 4-20 mA output from a 9 to 30 VDC power supply. Electrically similar to the ICA5S with the addition of intrinsic safety certification, it is the only ICA model approved for use in explosive and hazardous atmospheres.

PRODUCT DETAILS

The ICA family of subminiature signal conditioners is purpose-built to be embedded directly inside load cells, pressure transducers, torque transducers, and other strain gauge-based sensors. By placing the amplifier at the point of measurement, cable length between the gauges and amplifier is minimized, dramatically reducing susceptibility to electromagnetic interference from noise-generating equipment.

Available in seven variants to cover every output and power supply requirement:

  • ICA1H: 3-wire, 0.1 to 10.1 VDC output; 13 to 28 VDC power supply. The widest voltage output range in the family, ideal for systems requiring a full 0 to 10 V span referenced to a common supply rail.
  • ICA2H: 3-wire, 0.1 to 5.1 VDC output; 8.5 to 28 VDC power supply. The lowest minimum supply voltage among the voltage-output ICAH models, making it the right choice where only a 9 to 12 VDC supply is available.
  • ICA3H: 4-wire, ±10 VDC output, ±13 to ±15 VDC bipolar power supply. Delivers a true bipolar output for systems that require both positive and negative signal representation (tension and compression); requires a split power supply.
  • ICA6H: 3-wire, ±10 V output; +14 to 27 VDC power supply. Slightly taller than other models (7.6mm) at 10.8 mm.
  • ICA4H: 3-wire, 4-20 mA output; 13 to 28 VDC supply. Industry standard 4-20mA output that supports both source and sink wiring modes and the widest bridge sensitivity range (up to 150 mV/V).
  • ICA5S: 2-wire, 4-20 mA output; 7.5 to 28 VDC supply. Industrial-grade two-wire connection and the lowest minimum supply in the family.
  • ICA5ATEX: 2-wire loop powered 4-20 mA output; 9 to 28 VDC supply. ATEX intrinsically safe certified for use in explosive and hazardous atmospheres.

All models share the same 19.5 mm diameter PCB (ICA6H: 10.8 mm tall; all others: 7.6 mm tall), standardized 5 or 1.11 VDC bridge excitation, a single M2 mounting hole, multilayer PCB construction with additional EMC filtering, and RoHS compliance. An optional ILE field enclosure converts any ICA-equipped load cell into a conditioned-output sensor for external installations.

Output Signal

4-20 mA (2-wire, loop-powered)

Power Supply

9 to 30 VDC

Bridge Sensitivity

0.5 to 55 mV/V

Bridge Excitation

1.11 V DC

Input Range

Linearity

0.02 %FR

Operating Temperature

-40°C to +85°C (-40°F to +185°F)

IP Rating

IP67 ILEATEX enclosure

Enclosure Material

Stainless steel (ILEATEX enclosure)

Dimensions

19.5 mm diameter x 7.6 mm height (0.77″ x 0.30″)