500 DOUBLE ENDED SHEAR BEAM
This double ended shear beam load cell is designed for center loading and is ideally suited for large capacity weighing. Common applications includes truck, railway track and tank weighing. This precision load cell is can meet legal-for-trade requirements.
|
 |
|
Capacity
(Pounds)
|
A
(mm) |
B
(mm)
|
C
(mm) |
D
(mm) |
E
(mm) |
F
(mm) |
G
(mm) |
H
(mm) |
I
(mm) |
J
(mm) |
| 25,000 |
165 |
197 |
127 |
35 |
43 |
43 |
49 |
18 |
19 |
23 |
| 50,000 |
216 |
260 |
162 |
49 |
62 |
67 |
75 |
27 |
25 |
35 |
| 60,000 |
216 |
260 |
162 |
49 |
62 |
67 |
75 |
27 |
25 |
35 |
| 75,000 |
216 |
260 |
162 |
49 |
62 |
67 |
75 |
27 |
25 |
35 |
| 100,000 |
324 |
387 |
228 |
80 |
74 |
87 |
98 |
40 |
38 |
46 |
| 200,000 |
387 |
489 |
286 |
102 |
97 |
130 |
147 |
41 |
51 |
60 |
SPECIFICATIONS
| Capacities |
25,000 lb to 200,000 lb load cell capacities |
| Safe Overload |
150% full scale safe overload |
| Ultimate Overload |
300% full scale ultimate overload |
| Full Scale Ouput |
3 +/- 0.25% mv/v |
| Maximum Excitation |
15 volts DC |
| Operating Temp |
-50°C to +80°C |
| Compensated Temp |
-10°C to +40°C |
| Thermal Zero Shift |
0.00155 full scale / degree F |
| Sealing Standard |
IP-67 protected against high pressure jets of water |
| Non Linearity |
+/- 0.03% full scale |
| Material |
Nickel plated high strength alloy steel |
| Bridge Resistance |
700 Ohm |
|